AI systems generate structured, high-fidelity data.
Legacy systems do not preserve it.

During Translation, Data Is
Truncated
Reinterpreted
Silently dropped
That Loss Is
Invisible
Unmeasured
Non-recoverable
CORD Introduces
A deterministic envelope
A scoring system (EFS)
Measurable fidelity
Without vs With CORD
✗ Without CORD

AI Output → Legacy System → Data Loss

  • Fields dropped silently
  • No audit trail
  • No visibility into degradation
// AI intake output
{
  "chief_complaint": "chest pain, onset 3h, left arm",
  "icd10_codes": ["R07.9","R07.4","I20.9"],
  "allergy_list": ["penicillin","sulfa"]
}
↓ legacy EHR translation
// EHR output — 61% fidelity lost
{ "chief_complaint": "chest pain" }
✓ With CORD

AI Output → CORD Envelope → Legacy System → EFS

  • Data preserved in structured envelope
  • Translation is measurable
  • Fidelity loss is tracked and auditable
// CORD envelope
{
  "cord_version": "1.0",
  "envelope_type": "snapshot",
  "fields": { ... },
  "legacy_output": { "chief_complaint": "chest pain" },
  "loss_report": { "efs": 0.61 }
}
// EFS 0.61 — 39% loss measured & recorded
Open Specification · Apache 2.0 · v1.0.1

The standard for how
AI data survives
real-world systems.

CORD sits between AI systems and legacy software, ensuring structured data is preserved, translated, and measurable across every interaction.

JSON standardized how data is structured. CORD standardizes how AI-generated data survives translation.

⚠

If your system cannot measure data loss, it cannot trust its own outputs. CORD makes loss visible, auditable, and comparable across every translation.

→

Active implementations are currently being tested in production pipelines involving CRM systems, intake platforms, and AI-driven workflows.

Open Specification Apache 2.0 Licensed Domain-Agnostic application/cord+json Community-Governed

AI systems are the new interface for data collection. Legacy systems were never designed to receive them.

Why now

AI systems are now the primary interface for data collection across healthcare, automotive, real estate, finance, and HR. Legacy systems — CRMs, EHRs, DMSs, ATSs — were built for form fields and flat schemas. They were never designed to receive structured AI output. Without a protocol layer, information loss is inevitable — and currently invisible. No standard exists to measure it. CORD changes that.

As AI becomes the primary interface for data collection, a protocol layer for preserving structured output becomes unavoidable. The question is not whether this layer will exist — it is whether it will be standardized or fragmented. CORD is the standardized answer.

Source
AI Systems
LLMs · Agents · Voice AI · Chatbots
↓
structured output
Protocol Layer
CORD
Envelope · Versioning · Translation · EFS · Integrity
↓
legacy-formatted output + EFS score
Target
Legacy Systems
CRM · EHR · DMS · ATS · ERP

What CORD is not

CORD occupies a precise layer. Understanding what it is not prevents misclassification and accelerates adoption decisions.

✗
Not a CRM
CORD does not store, manage, or retrieve customer records. It structures and measures the data going into them.
✗
Not an API standard
CORD is transport-agnostic. It defines envelope semantics, not endpoints, authentication, or request schemas.
✗
Not a data warehouse
CORD does not define storage, querying, or analytics. It defines the format and fidelity of data in transit.
✗
Not a messaging protocol
CORD is not a transport layer. It runs on top of HTTP, queues, or any mechanism — not instead of them.

Without CORD vs. with CORD

Without CORD
  • No structured envelope for AI-generated data
  • No versioning model for interaction state
  • No standard for dual-format output
  • No measurement of information loss
  • No per-field mapping status
  • No auditable fidelity metric
  • No conformance model for implementing systems
  • Data loss is invisible, unaudited, and unmeasured
With CORD
  • Canonical Interaction Envelope for all AI output
  • Snapshot and delta versioning with parent references
  • Dual-format output: full-fidelity + legacy representation
  • EFS: normalized fidelity score per translation
  • FULL / PARTIAL / NONE mapping status per field
  • Machine-readable loss report per envelope
  • Four-tier conformance model including CORD-compatible
  • Data loss is measured, recorded, and auditable

Why existing standards are insufficient

StandardPurposeGap relative to CORD
JSON / XMLGeneric serializationNo interaction semantics, versioning, or loss model
OpenAPI / GraphQLAPI schema definitionDefines transport contracts, not content fidelity
HL7 FHIRHealth data exchangeDomain-specific; no fidelity measurement; not AI-native
CloudEventsEvent metadataTransport-layer; no interaction content or fidelity
ActivityStreamsSemantic activity modelingNo legacy translation model or loss quantification

Protocol architecture

CORD operates at the data layer — above transport protocols, below application business logic. Six core concepts constitute a complete interaction fidelity protocol.

Envelope
Interaction Envelope
Canonical structured container for a discrete AI-generated interaction event, including fields, dual-format output, loss report, and event log.
Required
Versioning
Snapshot & Delta
Full-state snapshots and incremental delta envelopes form version chains. Each delta references its parent by UUID and increments a monotonic version counter.
Required
Output
Dual-Format Output
Every envelope carries a full-fidelity CORD-native representation and a legacy-format output side by side, enabling direct comparison and downstream routing.
Required
Metric
Envelope Fidelity Score
EFS is a normalized score [0.0–1.0] measuring the proportion of information preserved when translating to the legacy format. Reported per envelope with per-field status.
Required
Integrity
Envelope Digest
SHA-256 cryptographic hash of the canonical JSON serialization, stored as x_cord_digest. Enables tamper detection at the data layer without external signing infrastructure.
Recommended
Events
Event Log
Ordered, typed, timestamped record of discrete events — utterances, classifications, signals — that produced the envelope's field state. Complete audit trail.
Optional
Media Type
application/cord+json
Registered media type for CORD-serialized envelopes. Use in Content-Type headers for HTTP. Implementations MUST produce valid JSON.
Required

Data flow

01
Collect
AI system collects structured interaction data
→
02
Envelope
Map into CORD Interaction Envelope
→
03
Version
Classify as snapshot or delta
→
04
Translate
Generate full-fidelity + legacy output
→
05
Score
Compute EFS and loss report
→
06
Seal
Compute SHA-256 digest
→
07
Transmit
Serialize as application/cord+json

Envelope structure

The CORD Interaction Envelope is the canonical container for a single interaction event. All required fields must be present for CORD-compliant serialization.

Top-level fields

Required and optional columns match the published envelope schema. Fields marked optional may be omitted entirely — for example, an AI-to-AI handoff envelope omits target_system, legacy_output, and the legacy efs.

FieldTypeRequiredDescription
cord_versionstringYesSpec version in use — e.g. "1.0"
envelope_idstring (UUID)YesGlobally unique envelope identifier
envelope_typeenumYes"snapshot", "delta", or "handoff"
versionintegerYesMonotonic counter within a version chain
parent_envelope_idstring (UUID)OptionalUUID of parent envelope; omitted for chain roots
created_atstring (ISO 8601)YesUTC creation timestamp
domainstringYesClassification domain — e.g. "healthcare"
source_systemstring | objectYesOriginating AI system. String, or {system_id, model} object
target_systemstring | objectOptionalTarget system. Omitted for AI-to-AI handoffs that have no legacy target
fieldsobjectYesObject keyed by field name; each value is a field object (see below)
legacy_outputobjectOptionalFlattened legacy-format representation; omitted when there is no legacy translation
loss_reportobjectOptionalEFS score and per-field mapping status; present whenever a translation or handoff is scored
event_logarrayOptionalOrdered list of typed interaction events
x_cord_digeststringRecommendedSHA-256 digest for envelope integrity. Format: "sha256:<hex>". See Security.

Field object structure

fields is an object keyed by field name. Each value is a field object:

PropertyTypeDescription
valueanyField value — string, number, array, or object
typestringSemantic type — e.g. "text", "code", "date", "structured"
confidencefloat [0.0–1.0]AI system confidence in this field value
sourcestringValue origin — e.g. "nlp", "user_input", "classifier"
changedbooleanTrue if field changed from parent (delta envelopes only)

Envelope examples

Snapshot
Delta
{
  "cord_version": "1.0",
  "envelope_id": "a3f9c201-7d42-4b1a-9e0f-2c88d3f5ab01",
  "envelope_type": "snapshot",
  "version": 1,
  "created_at": "2025-09-14T10:22:00Z",
  "domain": "healthcare",
  "source_system": "intake-ai-v2",
  "target_system": "epic-ehr-adapter",
  "fields": {
    "chief_complaint": { "value": "chest pain, onset 3 hours ago, radiating to left arm", "type": "text", "confidence": 0.97, "source": "nlp" },
    "icd10_codes": { "value": ["R07.9", "R07.4", "I20.9"], "type": "code_array", "confidence": 0.84, "source": "classifier" },
    "pain_score": { "value": 7, "type": "integer", "confidence": 0.92, "source": "nlp" }
  },
  "legacy_output": { "chief_complaint": "chest pain", "icd10_primary": "R07.9", "pain_score": "7" },
  "loss_report": { "efs": 0.61, "field_mappings": [
    { "field": "chief_complaint", "status": "PARTIAL", "partial_coefficient": 0.5, "note": "Radiation and onset detail truncated" },
    { "field": "icd10_codes", "status": "PARTIAL", "partial_coefficient": 0.62, "note": "Primary code only; 2 of 3 codes lost" },
    { "field": "pain_score", "status": "FULL", "note": "Value preserved; type coerced to string" }
  ]},
  "event_log": [
    { "event_type": "utterance", "timestamp": "2025-09-14T10:20:14Z", "actor": "patient", "content": "I have chest pain" },
    { "event_type": "classification", "timestamp": "2025-09-14T10:20:15Z", "actor": "intake-ai-v2", "field": "icd10_codes" }
  ],
  "x_cord_digest": "sha256:e4a7c3f901b2d844a1e09f3bc20d1847e4a7c3f901b2d844a1e09f3bc20d1847"
}
{
  "cord_version": "1.0",
  "envelope_id": "b7d1e443-2a91-4c8f-af20-d07c91f3bc12",
  "envelope_type": "delta",
  "version": 2,
  "parent_envelope_id": "a3f9c201-7d42-4b1a-9e0f-2c88d3f5ab01",
  "created_at": "2025-09-14T10:28:00Z",
  "domain": "healthcare",
  "source_system": "intake-ai-v2",
  "fields": { "pain_score": { "value": 9, "confidence": 0.95, "changed": true } },
  "legacy_output": { "pain_score": "9" },
  "loss_report": { "efs": 1.0, "field_mappings": [{ "field": "pain_score", "status": "FULL" }] },
  "x_cord_digest": "sha256:b9c2d7f1e30a5621c4890fd2b9c2d7f1e30a5621c4890fd2b9c2d7f1e30a5621"
}
ℹ
Version chaining: A sequence of envelopes — one snapshot followed by one or more deltas — is a version chain. The chain root is always a snapshot. Consumers MAY materialize full state at any point by applying deltas forward from the root.

Envelope Fidelity Score (EFS)

EFS is a normalized metric on [0.0, 1.0] quantifying the proportion of semantic information preserved when a CORD envelope is translated into a legacy format. It is a required output of every CORD-compliant translation — and a publishable benchmark for any implementing system.

EFS: 0.61 means 39% of structured data fidelity was lost during translation. The remaining 61% was preserved in the legacy system. The loss is now visible, measured, and recorded.

0.90 – 1.00
High Fidelity
All or nearly all structured content preserved. Minor type coercion may have occurred. Legacy record is a reliable representation of source data.
0.50 – 0.89
Moderate Fidelity
Meaningful content preserved but significant information was lost. Review field_mappings to understand the distribution of loss across fields.
0.00 – 0.49
Low Fidelity
Most structured content lost in translation. Indicates a significant schema capability gap in the target system. Legacy system modernization recommended.

Mapping status taxonomy

StatusMeaningFidelity contribution
FULLField value completely represented in legacy output.Maximum weight contribution to EFS
PARTIALField value partially represented. Some semantic content preserved; meaningful information was discarded or truncated.Coefficient in range [0.5, 0.9] — baseline default is 0.5.
NONEField could not be represented in legacy output. No information from this field exists in the legacy record.Zero contribution to EFS

EFS output structure

loss_report objectapplication/cord+json
{
  "efs": 0.74,
  "field_mappings": [
    { "field": "primary_diagnosis", "status": "FULL", "note": "Mapped to primary_dx without loss" },
    { "field": "symptom_history", "status": "PARTIAL", "note": "Duration and progression context truncated" },
    { "field": "differential_diagnoses", "status": "NONE", "note": "Target schema has no field for differential list" }
  ]
}
⚠
EFS is a translation metric, not a data quality metric. A score of 1.0 indicates the translation was faithful to the source — not that the source data is accurate or complete.

EFS is computed as a weighted aggregate of per-field fidelity contributions: FULL = 1.0, PARTIAL = 0.5 baseline (range 0.5–0.9, implementation-defined), NONE = 0.0.

Confidence-based coefficient selection

When AI confidence scores are available on source fields, implementations SHOULD use them to refine the PARTIAL coefficient. A field with low confidence receives a coefficient at the lower bound (0.5); a field with high confidence may receive a coefficient toward the upper bound (0.9).

Confidence propagationPARTIAL coefficient selection
if (confidence < low_threshold)   → coefficient = 0.5
if (confidence >= high_threshold)  → coefficient = 0.9
otherwise                          → linear interpolation in [0.5, 0.9]

Display format

EFS is computed and stored as a decimal in [0.0, 1.0]. User interfaces MAY display EFS as a percentage for human readability. Implementations MUST NOT store the percentage form in place of the decimal in any envelope, log, or downstream record.

Auditable PARTIAL coefficients

When a field's mapping status is PARTIAL, the resolved coefficient SHOULD be recorded in the partial_coefficient property of the field mapping entry. This enables full auditability of EFS computation.

Envelope integrity and protection

CORD envelopes may contain sensitive personal, medical, or financial data. The protocol defines mechanisms for tamper detection, replay protection, and data confidentiality at the envelope layer.

Integrity
SHA-256 Envelope Digest
Every envelope SHOULD include an x_cord_digest field containing a SHA-256 hash of the canonical JSON serialization (excluding the digest field itself). Format: sha256:<hex>.
Protection
Replay Protection
Implementations SHOULD validate envelope_id uniqueness at ingestion and reject envelopes with a created_at timestamp older than an implementation-defined staleness threshold.
Transport
Encryption
Implementations MUST apply appropriate encryption in transit (TLS 1.2 minimum) and at rest. CORD does not define encryption mechanisms — these are the responsibility of the implementing system.

Digest computation

SHA-256 Envelope Integrityx_cord_digest
// 1. Serialize envelope to canonical JSON (sorted keys, no whitespace)
canonical = json_serialize(envelope, sort_keys=true, separators=[",",":"])
// 2. Exclude x_cord_digest field before hashing
delete canonical["x_cord_digest"]
// 3. Compute SHA-256
digest = sha256(canonical)
// 4. Store as extension field
envelope.x_cord_digest = "sha256:" + hex(digest)
ℹ
Confidence scores are AI-generated estimates and MUST NOT be treated as guarantees. Downstream systems that make decisions based on field values SHOULD consider the associated confidence score.

When to use CORD

CORD is required when
  • AI-generated structured data passes through legacy or third-party systems
  • Data transformations occur across system boundaries
  • Fidelity, traceability, or auditability are critical
CORD is not required when
  • Systems are natively interoperable with no schema mismatch
  • No transformation or interpretation occurs during transit
  • Data fidelity is not a concern for the use case

Conformance model

CORD defines four conformance levels. Conformance is assessed at the level of a complete translation pipeline — the originating AI system, the translation process, and the target legacy system.

Validation categories

Legacy-translation conformance is assessed against three base validation categories that every CORD-compliant envelope MUST pass. CORD v1.1 adds a fourth category that applies only to AI-to-AI handoff envelopes:

CategoryNameValidates
1Envelope StructureAll required fields present, correctly typed, structural constraints satisfied
2EFS Reportingloss_report present with valid EFS in [0.0, 1.0], field_mappings array with valid FULL/PARTIAL/NONE status on every entry
3Mapping CompletenessEvery source field in fields has a corresponding entry in loss_report.field_mappings — no silent omissions
4Handoff-Aware v1.1Applies when the envelope is a handoff. Verifies that the sender attached the fidelity baseline (required_claims and producer_attestation), that handoff_chain is present and correctly ordered, and that the receiver computed handoff_efs against the baseline and returned it in loss_report.
ℹ
Category 4 is conditional. Categories 1 through 3 validate every translation and apply to every CORD envelope. Category 4 (Handoff-Aware) applies only to handoff envelopes — it adds the handoff fidelity contract on top of the base checks. A system that never emits handoffs remains fully CORD-Compliant on Categories 1–3 alone. Meeting all four earns the CORD-Compliant (Handoff-Aware) designation. Full definition in the AI Contract profile; carriage over MCP and A2A in Transport Bindings.

Four conformance tiers

CORD-Compliant

Fully satisfies all CORD specification requirements.

  • Valid envelope with all required fields
  • Correct snapshot / delta classification
  • Monotonic version counter; parent references on all deltas
  • Loss report with EFS per translation
  • FULL / PARTIAL / NONE status on every source field
  • Serialized as application/cord+json
CORD-Partial

Satisfies core requirements; optional features may be omitted.

  • Valid envelope with required fields
  • Loss report with an EFS value
  • Serialized as application/cord+json
  • MAY omit: event log, per-field notes, version chaining
CORD-Compatible

Produces or consumes CORD envelopes in part, or is in active migration.

  • Can parse or emit core CORD envelope fields
  • Does not yet produce full EFS or per-field mapping status
  • Appropriate for systems migrating toward CORD-Partial or CORD-Compliant
Non-Compliant

Does not participate in the CORD ecosystem.

  • No CORD-structured envelope produced
  • No EFS or loss report generated
  • Translation occurs without structured loss measurement

Non-compliant indicates the system does not participate in the CORD ecosystem — not that it is defective.

ℹ
CORD-compatible lowers adoption friction. Systems that produce or consume CORD envelopes partially — or are mid-migration — can declare compatibility without claiming full conformance.

Reference examples

CORD envelopes across four domains. Each shows the AI-collected structured data, the compressed legacy output, and the resulting EFS.

Healthcare — Patient IntakeEFS: 0.61

AI intake assistant captures structured patient data during a voice interaction. Target: legacy EHR with a constrained schema.

Fields → Legacy Output → Loss Reportdomain: healthcare
{
  "fields": {
    "chief_complaint": { "value": "chest pain, onset 3h, left arm radiation, 7/10", "confidence": 0.97 },
    "icd10_codes": { "value": ["R07.9", "R07.4", "I20.9"], "confidence": 0.84 },
    "pain_score": { "value": 7, "confidence": 0.92 },
    "allergy_list": { "value": ["penicillin", "sulfa"], "confidence": 0.99 }
  },
  "legacy_output": { "chief_complaint": "chest pain", "icd10_primary": "R07.9", "pain_score": "7", "allergies": "penicillin, sulfa" },
  "loss_report": { "efs": 0.61, "field_mappings": [
    { "field": "chief_complaint", "status": "PARTIAL" },
    { "field": "icd10_codes", "status": "PARTIAL" },
    { "field": "pain_score", "status": "FULL" },
    { "field": "allergy_list", "status": "FULL" }
  ]}
}
Automotive — Customer Vehicle InquiryEFS: 0.81

AI sales assistant captures structured customer intent during a dealership inquiry. Target: legacy DMS with a flat lead record.

Fields → Legacy Output → Loss Reportdomain: automotive
{
  "fields": {
    "vehicle_interest": { "value": { "make": "Toyota", "model": "Camry", "year": 2025, "trim": "XSE" }, "confidence": 0.95 },
    "budget": { "value": { "max_monthly": 650, "down_payment": 5000 }, "confidence": 0.88 },
    "trade_in": { "value": { "make": "Honda", "model": "Civic", "year": 2019, "mileage": 48200 }, "confidence": 0.91 }
  },
  "legacy_output": { "vehicle_interest": "2025 Toyota Camry XSE", "monthly_budget": 650, "trade_make": "Honda", "trade_model": "Civic", "trade_year": 2019 },
  "loss_report": { "efs": 0.81, "field_mappings": [
    { "field": "vehicle_interest", "status": "FULL" },
    { "field": "budget", "status": "PARTIAL" },
    { "field": "trade_in", "status": "FULL" }
  ]}
}

Quick Start

Core operations required to produce a CORD-compliant envelope. Examples use pseudocode; any language or serialization library may be used.

1. Initialize an envelope

Pseudocode — Initialization
envelope = {
  cord_version: "1.0", envelope_id: generate_uuid(),
  envelope_type: "snapshot", version: 1,
  parent_envelope_id: null, created_at: utc_now_iso8601(),
  domain: "healthcare", source_system: "my-ai-system",
  target_system: "target-crm", fields: {}, legacy_output: {}, loss_report: {}, event_log: []
}

2. Add structured fields

Pseudocode — Field Population
envelope.fields["patient_name"] = { value: "Jane Smith", type: "text", confidence: 0.99, source: "user_input" }
envelope.fields["symptoms"]     = { value: ["headache", "nausea"], type: "text_array", confidence: 0.87, source: "nlp" }

3. Serialize to application/cord+json

Pseudocode — Serialization
payload = json_serialize(envelope)
http_post(url: "https://target.example.com/intake", headers: { "Content-Type": "application/cord+json" }, body: payload)

4. Compute the loss report

Pseudocode — EFS Computation
loss_report = { efs: 0.0, field_mappings: [] }
total_weight = 0; fidelity_sum = 0
for name, field in envelope.fields:
  status = assess_mapping(field, target_schema)
  loss_report.field_mappings.append({ field: name, status: status })
  fidelity_sum += get_field_weight(field) * fidelity_coefficient(status)
  total_weight += get_field_weight(field)
if total_weight > 0: loss_report.efs = round(fidelity_sum / total_weight, 2)

Adopt CORD

CORD is an open specification. There is no registration required to implement it.

01
Implement the specification
Produce CORD-structured envelopes in your AI pipeline. Start with CORD-compatible or CORD-partial conformance. No registration or approval required.
Read the Quick Start →
02
Use the reference engine
The CORD Engine is a standalone open-source implementation of the full v1.0 spec — envelope builder, field mapper, EFS scorer, domain adapters, and a REST API. Apache 2.0.
View Engine Repo ↗
03
Observe your EFS
EFS values live inside every CORD envelope your system produces. Route them into existing observability stacks — Datadog, Splunk, Grafana, Prometheus, or internal BI. No central CORD dashboard.
View reference dashboard ↗
04
Declare CORD compatibility
Declare your conformance level in product documentation, API responses, or integration guides. Standard language: "This system produces CORD-compliant envelopes (v1.0)."
View conformance levels →
05
Publish your EFS
Systems that publicly report their average EFS by domain make the protocol ecosystem more transparent. Include methodology notes alongside any published score.
EFS reference →
ℹ
Early adopters implementing CORD in production are encouraged to open an issue on the spec repo to be listed in the adopter registry.

Frequently asked questions

Is CORD an open specification?
Yes. CORD is published as an open specification under the Apache 2.0 license. Any system, vendor, or individual developer may implement it without licensing fees or prior authorization.
Is CORD a product or a SaaS platform?
No. CORD is a protocol specification — a set of rules for structuring, versioning, translating, and measuring AI-generated interaction data. It does not include a hosted service, managed runtime, or commercial offering. Any organization may implement CORD in their own systems.
How does CORD relate to existing APIs and integration standards?
CORD operates at the data layer, not the transport layer. It is compatible with any transport protocol — HTTP, message queues, file exchange, database writes. It complements API standards (REST, GraphQL, gRPC) by defining what the interaction payload should look like and how fidelity loss should be measured. It does not replace transport contracts.
What is the difference between CORD-compliant and CORD-compatible?
CORD-compatible is the lowest-friction entry point. A compatible system can produce or consume core CORD envelope fields without yet implementing full EFS reporting or per-field mapping status. It is appropriate for systems in active migration toward full conformance. CORD-compliant requires all required fields, a complete loss report, and full EFS output per translation.
Does CORD replace domain-specific standards like HL7 FHIR?
No. CORD wraps the translation layer between AI systems and whatever format a target system expects — including FHIR resources, ADF-XML, or proprietary CRM schemas. CORD does not prescribe the target format; it measures and records the fidelity of translation into it.
Who defines the EFS weighting model?
CORD defines the EFS concept, the mapping status taxonomy (FULL, PARTIAL, NONE), and the requirement that an EFS value be reported. The specific weighting algorithm is implementation-defined. Appropriate weights are domain- and context-dependent. Implementing systems are encouraged to publish their weighting methodology alongside any EFS scores they report publicly.
How is EFS different from data quality scoring?
EFS measures translation fidelity — the proportion of source information preserved in the target format — not the accuracy or completeness of the source data. A system can produce an EFS of 1.0 while the underlying data contains errors. EFS is a property of the translation step, not the upstream AI system's quality.
How do adopters monitor their EFS over time?
EFS values are carried inside every envelope your system produces. Adopters route those values into their existing observability stack — there is no central CORD service, and cordspec.org does not collect implementation metrics. Most teams ingest envelope EFS into the same telemetry pipeline they use for application-level metrics. A reference dashboard is available in the engine repository for teams that want a starting point — drop in a folder of .cord.json envelopes and view EFS distributions, per-field loss heatmaps, and binding-vs-actual gaps. Implementers that publicly report aggregate EFS by domain are listed in the adopter registry.
Should EFS be displayed as a decimal or a percentage?
EFS is stored and exchanged as a decimal in [0.0, 1.0] — this is the canonical form referenced in the spec and the conformance model. User interfaces MAY display EFS as a percentage for human readability (e.g. 0.84 shown as 84%), but the canonical value carried in the envelope is always the decimal form. Implementations that display the percentage form should surface the decimal form on detail or audit views, and must not store the percentage form in place of the decimal in envelopes, logs, or downstream records. See the Display format section of the EFS reference for details.
Is there a certification process?
CORD-compliant systems MUST pass three validation categories: (1) envelope structure — all required fields present and correctly typed; (2) EFS reporting — loss_report complete with valid status values and correctly computed score; (3) mapping completeness — every source field has a corresponding loss_report entry with no silent omissions. Systems that produce or consume the v1.1 handoff envelope type must additionally pass a fourth category: (4) handoff integrity — handoff_chain present, well-formed, and all referenced envelope_ids resolvable. Category 4 does not apply to systems that do not use handoff envelopes. A system that passes Category 4 may additionally claim the CORD-Compliant (Handoff-Aware) sub-designation. Self-assessment against the applicable categories is sufficient to declare CORD-compliant status under v1.0. A formal certification program with automated test suites and a public conformance registry is under development.
What is the minimum viable CORD implementation?
CORD-compatible is the lowest entry point — consuming or producing core envelope fields without full EFS. CORD-partial is the minimum for loss reporting: a valid envelope, an EFS value, and application/cord+json serialization. Event logs, version chaining, and envelope digest are optional at the partial tier.
How does envelope integrity work?
The x_cord_digest field contains a SHA-256 hash of the envelope's canonical JSON serialization (excluding the digest field itself). Any consumer can recompute the digest and compare — a mismatch indicates the envelope has been tampered with. This provides data-layer tamper detection without requiring external signing infrastructure or certificate management.
How does replay protection work?
Implementations that require replay protection validate that each envelope_id is unique at ingestion and reject envelopes with a created_at timestamp older than a configurable staleness threshold. This prevents duplicate processing of previously ingested envelopes.
How does confidence propagation work?
When a field is mapped as PARTIAL, the AI's confidence score on that field can drive the coefficient selection within the [0.5, 0.9] range. Low-confidence fields receive a coefficient near the floor (0.5); high-confidence fields can go toward the ceiling (0.9). The resolved coefficient is recorded in the partial_coefficient property for full auditability. This is optional but recommended.

Changelog

CORD versions follow MAJOR.MINOR format. MAJOR increments indicate breaking changes to envelope schema or EFS semantics. MINOR increments are additive and backwards-compatible.

v1.2.0
June 2026
Extension
  • New binding profile: CORDspec-over-A2A — carries the v1.1 envelope as an A2A structured-data part, returns EFS results as a structured-data part, advertises support via an AgentExtension in the Agent Card
  • New binding profile: CORDspec-over-MCP — carries the v1.1 envelope as tool-result structuredContent with a text fallback, returns EFS results as structuredContent, advertises support via tool _meta
  • States how Category 4 and the CORD-Compliant (Handoff-Aware) designation are satisfied over each binding; Categories 1–4 unchanged
  • Four reference payloads added
  • Pins: A2A v1.0.0, MCP revision 2025-11-25. No new transport, discovery, or auth. Measurement only, no enforcement
  • Backwards compatible with v1.0 and v1.1. See Transport Bindings profile for full spec.
v1.1.0
June 2026
Extension
  • New envelope_type: "handoff" for AI-to-AI exchange without a legacy translation step
  • handoff_chain array for tracking AI-to-AI lineage, oldest-first
  • required_claims optional field for explicit fidelity contracts (any envelope type)
  • producer_attestation required field on handoff envelopes
  • handoff_efs metric distinct from the legacy translation efs
  • loss_report gains handoff_efs and upstream_envelope_type keys
  • Category 4 (Handoff-Aware) added to validation categories — the handoff fidelity contract for AI-to-AI handoff envelopes
  • CORD-Compliant (Handoff-Aware) sub-designation for systems passing all four categories
  • Two reference examples: multi-agent sales pipeline and healthcare triage chain
  • Backwards compatible with v1.0. See AI Contract profile for full spec.
v1.0.1
May 2026
Clarification
  • Display format rule added to EFS reference: decimal canonical, percentage presentation-only
  • Observability guidance added to Adopt CORD
  • Two FAQ entries added covering observability and display format
  • No changes to envelope schema, EFS computation, conformance model, or required fields
v1.0
September 2025
Release
  • Initial public specification release
  • Canonical Interaction Envelope structure defined
  • Envelope Fidelity Score (EFS) introduced — normalized [0.0–1.0]
  • Four-tier conformance model including CORD-compatible
  • application/cord+json media type registered
  • SHA-256 envelope integrity via x_cord_digest
v0.9
June 2025
Pre-release
  • Internal draft for specification review
  • Initial EFS metric definition and loss coefficient model

Open specification, community-governed

CORD is an open specification maintained through a community governance process. It is not associated with any single vendor, platform, or product.

⚠
Status note: CORD v1.0 is maintained by its founding editors under community governance. A formal advisory board and RFC registry are planned as adoption scales.

Specification Process

Changes proceed through a public proposal and comment process. Anyone may submit proposals. Changes to required fields require supermajority of active maintainers.

Planned: Advisory Board

A 5–9 member advisory board representing AI system builders, legacy software vendors, enterprise integrators, and independent contributors.

Breaking Changes

Changes to required fields or envelope structure require supermajority approval and a 12-month deprecation notice. Migration guides are published before every major release.

Conformance Validation

CORD-compliant systems MUST pass three validation categories: envelope structure, EFS reporting, and mapping completeness. Systems that implement the v1.1 handoff envelope type additionally MUST pass a fourth category — Handoff-Aware — to earn the CORD-Compliant (Handoff-Aware) sub-designation; systems that do not use handoff envelopes are unaffected. Self-assessment is sufficient under v1.0.

Open Participation

The specification, schema, and all reference tooling are Apache 2.0 licensed. Contributions are welcome via GitHub pull request and public issue tracker.

Specification Stages

Concept → Draft → Candidate → Release → Deprecated. CORD v1.0 is at Release status. Stage transitions are documented in the changelog.

ℹ
Neutrality: References to specific systems, formats, or technologies in this document are illustrative only and do not constitute endorsement or affiliation. CORD is not a product of any company.